Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
China Pharmacist ; (12): 18-19,20, 2015.
Article in Chinese | WPRIM | ID: wpr-600719

ABSTRACT

Objective:To establish a method for the determination of dichloromethane, methanol and ethanol in fenticonazole ni-trate. Methods:The samples were detected by headspace GC. The column was OV-1301(30 m × 0. 53 mm,3. 0 μm), the detector was FID with nitrogen as the carrier gas, the detector temperature was 250 ℃ and the injector temperature was 200 ℃. Results:The linear range of dichloromethane, methanol and ethanol was 2. 436-21. 924(r=0. 998 8), 12. 268-110. 412(r=0. 999 5) and 20. 052-180. 468 μg·ml-1(r=0. 996 9) with the average recovery of 99. 30% (RSD=2. 36%), 100. 21%(RSD=1. 07%) and 100. 15%(RSD=1. 21%)(n=9), respectively. Conclusion:The detection method is sensitive, accurate and reliable, and can be used in the quality control of fenticonazole nitrate.

2.
Herald of Medicine ; (12): 1072-1074, 2015.
Article in Chinese | WPRIM | ID: wpr-477710

ABSTRACT

Objective To establish a gas chromatograph method for determing Chloroform, ethyl acetate and N, N-dimethyl formamide in butoconazole nitrate. Methods The samples was detected by Headspace Gas Chromatography. Temperature programming method was adpoted and FID was used as detector. The injector temperature was 200 ℃, and the detector temperature was reach 250 ℃. Nitrogen was used as carrier gas in the experiment. Results In the mentioned chromatographic conditions, Chloroform, ethyl acetate and N, N-dimethyl formamide had good linear relationships in the ranges of 0. 066-0. 588,0. 062-0. 556 and 0. 896-8. 061 μg·mL-1 respectively. The average recoveries were 99. 18%,102. 84% and 98. 71%. RSD were 3. 87%,4. 33% and 3. 71%. Conclusion The detection method is sensitive, accurate, reliable, and can be used as a quality control for butoconazole nitrate.

3.
China Pharmacist ; (12): 563-565, 2014.
Article in Chinese | WPRIM | ID: wpr-448071

ABSTRACT

Objective:To determine the content of chloroform, ethyl acetate and DMF in dimemorfan phosphate by gas chromatog-raphy (GC). Methods:The capillary gas chromatography was used with a PEG-20M column, programmed temperature, water as the solvent and FID as the detector. Results:The three organic solvents were separated and showed good linear relationship (r>0. 999 0). The detection limit of chloroform, ethyl acetate and DMF was 0. 63,0. 60 and 8. 92μg·ml-1 , respectively. The residues of the organ-ic solvents in three batches of the samples all met with the requirements of ICH. Conclusion: The method is sensitive, accurate and reliable, and can be used in the quality control of dimemorfan phosphate.

SELECTION OF CITATIONS
SEARCH DETAIL